Cryogenic micromachining of soft and stretchable polymer for wearable sensing devices

Authors

  • Partha Sarathi Mallick Indian Institute of Technology Patna, Patna, India
  • Akshay Saxena Indian Institute of Technology Patna, Patna, India
  • Karali Patra Indian Institute of Technology Patna, Patna, India

DOI:

https://doi.org/10.58368/MTT.22.4.2023.39-44

Keywords:

Micro-Milling, Cryogenic, Glass Transition Temperature, Soft Polymer, VHB

Abstract

A growing number of microchannel applications, particularly high-actuating wearable sensing devices, need novel fabrication techniques for acrylic-based soft polymer. Fabricating microchannel patterns on such soft polymers is highly challenging with the conventional lithography process due to their unpredictable mechanical response to deformation. Mechanical micro-milling process is a feasible method to fabricate various microchannel patterns. However, mechanical micromilling has not yet been applied to soft polymers like VHB (Very high bond) acrylic elastomer. Due to low elasticity and high adhesion, machining of VHB is nearly impossible at room temperature. In order to machine a microchannel, mechanical micro-milling is proposed in combination with the cryogenic cooling process to cut the VHB around glass transition temperature because of its remarkable change of property from rubbery to glassy state. In this study, cryogenic micro-milling experimental setup is fabricated based on glass transition characteristics of VHB. Fixed machining parameters are then used to evaluate the effectiveness of micro-milling of VHB at room and cryogenic temperature. The result of the cutting test shows that the microchannel can be fabricated in VHB by the proposed cryogenic machining technique. In this context, cutting force and channel microstructure were also analysed at different machining conditions.

Metrics

Metrics Loading ...

References

Chopra, S., Deshmukh, K.A., Somvanshi, M.V., Patil, N. V., Rakhe, S. R., Sontakke, R. V., Batthula, S., Konda, A. P., Waghmare, G., Anjali, A., Peshwe, D., Gogte, C. L., &Carlone, P. (2021). Structural Elucidation and Mechanical Behavior of Cryogenically Treated Ultra-High Molecular Weight Poly-ethylene (UHMWPE).Transactions of the Indian Institute of Metals, 74, 255-265 https://doi.org/10.1007/s12666-020-02140-2

Kakinuma, Y., Kidani, S., & Aoyama, T. (2012). Ultra-precision cryogenic machining of viscoelastic polymers.CIRP Annals - Manufacturing Technology, 61, 79-82.

Kakinuma, Y., Yasuda, N., & Aoyama, T. (2008).Micromachining of soft polymer material applying cryogenic cooling.Journal of Advanced Mechanical Design, Systems, and Manufacturing, 2, 560-569.

Mallick, P. S., Pratap, A., & Patra, K. (2022). Review on cryogenic assisted micro-machining of soft polymer : An emphasis on molecular physics, chamber design, performance analysis and sustainability. Journal of Manufacturing Processes, 80(May), 930-957. https://doi. org/10.1016/j.jmapro.2022.06.035

Peng, W., Han, L., Huang, H., Xuan, X., Pan, G., Wan, L., Lu, T., Xu, M., & Pan, L. (2020). A direction-aware and ultrafast self-healing dual network hydrogel for a flexible electronic skin strain sensor.Journal of Materials Chemistry A, 8(48), 26109-26118. https://doi.org/10.1039/ d0ta08987g

Sahu, R. K., & Patra, K. (2016).Rate-dependent mechanical behavior of VHB 4910 elastomer.Mechanics of Advanced Materials and Structures, 23(2), 170-179. https://doi.org/10.1 080/15376494.2014.949923

Sheng, J., Chen, H., Qiang, J., Li, B., & Wang, Y. (2012).Thermal, Mechanical, and Dielectric Properties of a Dielectric Elastomer for Actuator Applications.Journal of Macromolecular Science, Part B, 51(10), 2093-2104. https://doi. org/10.1080/00222348.2012.659617

Souri, H., Banerjee, H., Jusufi, A., Radacsi, N., Stokes, A. A., Park, I., Sitti, M., &Amjadi, M. (2020). Wearable and stretchable strain sensors: materials, sensing mechanisms, and applications. Advanced Intelligent Systems, 2(8), 2000039.https://doi.org/10.1002/aisy.2020 00039

Souri, H., & Bhattacharyya, D. (2018). Highly sensitive, stretchable and wearable strain sensors using fragmented conductive cotton fabric. Journal of Materials Chemistry C, 6(39), 10524-10531. https://doi.org/10.1039/ c8tc03702g

Wang, X., Lv, Y., Lv, S., Liu, H., & Ni, H. J. (2017).Effect of cryogenic treatment on microstructure and properties of acrylonitrile-butadiene-styrene.Emerging Materials Research, 6(1), 35-39. https://doi.org/10.1680/jemmr.16.00066

Xiao, K. Q., & Zhang, L. C. (2002).The role of viscous deformation in the machining of polymers.International Journal of Mechanical Sciences, 44(11), 2317-2336. https://doi.org/10.1016/ S0020-7403(02)00178-9

Downloads

Published

01-04-2023

How to Cite

Mallick, P. S., Saxena, A., & Patra , K. (2023). Cryogenic micromachining of soft and stretchable polymer for wearable sensing devices. Manufacturing Technology Today, 22(4), 39–44. https://doi.org/10.58368/MTT.22.4.2023.39-44

Issue

Section

Articles